{"format":"cadcraft-library-item","format_version":1,"uuid":"1c7d6ee3-e28c-449c-844d-fa9b18a8bd30","version":2,"name":"Poland: Rozporządzenie w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie (Dz.U. 2022…","kind":"regulation","category":"regulations/building","description":"Values for single-family houses (multi-family buildings: riser 175, width 1200, balustrade 1100). STATUS: ISAP lists this regulation as repealed from 2026-09-21; under the transition rules (Dz.U. 2026 poz. 1161) investors may design and build to it for 18 months (to about March 2028). No replacement found as of 2026-10-27. The going is a formula (2h + s = 600-650 mm) and the balustrade has only a…","maker":"","model":"","ifc":{"class":"IfcControl","predefined":"NOTDEFINED"},"plan":{"layers":[],"entities":[]},"body":null,"params":{},"regulation":{"format":"cadcraft-regulation-pack","version":1,"id":"pl-warunki-techniczne-2002","name":"Poland: Rozporządzenie w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie (Dz.U. 2022…","jurisdiction":{"country":"PL","level":"country","region":"","name":"Poland"},"base":null,"edition":"Rozporządzenie w sprawie warunków techn…","in_force":"2002-12-16","review":{"state":"draft","note":"Values for single-family houses (multi-family buildings: riser 175, width 1200, balustrade 1100). STATUS: ISAP lists this regulation as repealed from 2026-09-21; under the transition rules (Dz.U. 2026 poz. 1161) investors may design and build to it for 18 months (to about March 2028). No replacement found as of 2026-10-27. The going is a formula (2h + s = 600-650 mm) and the balustrade has only a…"},"authority":"adopted-law","source":{"name":"Minister Infrastruktury (now Minister Rozwoju i Technologii), Rozporządzenie w sprawie warunków technicznych, jakim pow…","url":"https://isap.sejm.gov.pl/isap.nsf/DocDetails.xsp?id=WDU20220001225","date":"2022-04-15","checked":"2026-10-27"},"maker":null,"price":null,"criteria":[],"tables":[],"rules":[{"id":"stair.riser.max","applies":"stair","op":"<=","unit":"mm","clause":"§ 68 ust. 1","label":"Riser height","note":"Single-family and farm houses, two-level apartments; 175 mm in multi-family buildings.","value":190},{"id":"stair.width.min","applies":"stair","op":">=","unit":"mm","clause":"§ 68 ust. 1, ust. 4","label":"Stair width","note":"Usable width between handrails, single-family; 1200 multi-family.","value":800},{"id":"room.ceiling.min","applies":"room","op":">=","unit":"mm","clause":"§ 72 ust. 1","label":"Ceiling height","note":"Rooms in residential buildings; 2200 for attic rooms in single-family houses (average height under sloped ceilings).","value":2500},{"id":"room.light.min","applies":"room","op":">=","unit":"pct","clause":"§ 57 ust. 2","label":"Glazing, share of floor area","note":"Window clear frame opening at least 1:8 of the floor area.","value":12.5},{"id":"room.vent.min","applies":"room","op":">=","unit":"pct","clause":"§ 155 ust. 1","label":"Openable area, share of floor area","note":"At least 50 % of the required window area opens (without mechanical ventilation).","value":6.25}]},"source_attrs":{},"license":{"id":"CC0-1.0","holder":"CadCraft","attribution":"“Poland: Rozporządzenie w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie (Dz.U. 2022…” by CadCraft (https://isap.sejm.gov.pl/isap.nsf/DocDetails.xsp?id=WDU20220001225), CC0 (https://creativecommons.org/publicdomain/zero/1.0/)","url":"https://creativecommons.org/publicdomain/zero/1.0/"},"provenance":{"library":"librarycraft","item":"1c7d6ee3-e28c-449c-844d-fa9b18a8bd30","version":2,"sha256":"8a89ca800513fbf4e8a5f5572b7082587617c475b41ebe1a505e813402d4aaef","source_file":"pl-warunki-techniczne-2002.json","source_sha256":"e1067aaab5f8eabe741ca8bb2950e23f701b20c8ed7ff32fe6f225c5e0c333d1","published_at":"2026-10-27T02:07:28Z"}}