{"format":"cadcraft-library-item","format_version":1,"uuid":"a9586376-567b-4521-9619-5f373f5cbf78","version":1,"name":"MADE-UP sample: drawing conventions and standard notes","kind":"regulation","category":"regulations/building","description":"MADE-UP. Every number and every note in this pack was invented to show how conventions and standard notes work. It is not any office's, city's or code's practice. Replace it with a pack for your own place.","maker":"","model":"","ifc":{"class":"IfcControl","predefined":"NOTDEFINED"},"plan":{"layers":[],"entities":[]},"body":null,"params":{},"regulation":{"format":"cadcraft-regulation-pack","version":1,"id":"us-sample-practice","name":"MADE-UP sample: drawing conventions and standard notes","jurisdiction":{"country":"US","level":"country","region":"","name":"Nowhere (teaching sample)"},"base":null,"edition":"made up","in_force":null,"review":{"state":"unchecked","note":"MADE-UP. Every number and every note in this pack was invented to show how conventions and standard notes work. It is not any office's, city's or code's practice. Replace it with a pack for your own place."},"authority":"community","source":{"name":"Made up for teaching: no source","url":"https://example.com/made-up","date":"","checked":"2026-11-11"},"maker":null,"price":null,"criteria":[],"tables":[],"rules":[],"release":{"version":"0.1.0","changelog":[{"version":"0.1.0","date":"2026-11-11","added":["Added: MADE-UP text heights, line weights, marks and standard notes to show how conventions and notes work (first version of this pack)","Added: a MADE-UP submission format"]}]},"submission":{"authority":"Nobody (MADE-UP)","summary":"MADE-UP submission format: invented to show how the permit package reads a pack. No authority asks for this.","sources":[{"title":"MADE-UP: no real source","url":"https://example.com/made-up","fetched":"2026-11-11","licence":"Invented for teaching."}],"format":{"sheetSizes":["a1","a3"],"orientation":"landscape","fileFormats":["pdf"],"maxFileMB":20,"copies":{"text":"MADE-UP: two paper sets and one file","paper":2,"electronic":1},"stampSpace":"MADE-UP: keep the top-right corner free","titleBlock":{"fields":[{"key":"project","label":"Project","words":["project","job"]},{"key":"drawnby","label":"Drawn by","words":["drawn","author"]},{"key":"date","label":"Date","words":["date"]}]},"note":"MADE-UP sample.","source":0},"drawings":[{"id":"site-plan","title":"Site plan (MADE-UP)","detail":"MADE-UP: the lot and the building on it.","clause":"MADE-UP S1","when":"always","source":0,"scale":{"text":"1:200 or larger (MADE-UP)","maxDenominator":200},"satisfy":[{"words":["site plan"]}],"site":true},{"id":"floor-plans","title":"Floor plans (MADE-UP)","detail":"MADE-UP: one plan per level.","clause":"MADE-UP S2","when":"always","source":0,"satisfy":[{"view":["plan"]}],"site":false}],"documents":[{"id":"application-form","title":"Application form (MADE-UP)","detail":"MADE-UP: a form you fill in yourself.","clause":"MADE-UP S3","when":"always","source":0}]},"conventions":{"sources":[{"title":"MADE-UP: no real source","url":"https://example.com/made-up","fetched":"2026-11-11","licence":"Invented for teaching."}],"text":[{"id":"notes","use":"General notes (MADE-UP)","kind":"text","clause":"MADE-UP 1","min":true,"source":0,"mm":3},{"id":"dimensions","use":"Dimensions (MADE-UP)","kind":"dimension","clause":"MADE-UP 2","min":true,"source":0,"mm":2.5},{"id":"titles","use":"View titles (MADE-UP)","kind":"title","clause":"MADE-UP 3","min":false,"source":0,"mm":5}],"lines":[{"id":"cut","use":"Cut walls (MADE-UP)","clause":"MADE-UP 4","source":0,"mm":0.5},{"id":"visible","use":"Visible edges (MADE-UP)","clause":"MADE-UP 4","source":0,"mm":0.25},{"id":"hidden","use":"Hidden edges (MADE-UP)","clause":"MADE-UP 4","source":0,"mm":0.13}],"marks":[{"id":"north","label":"North point on every plan (MADE-UP)","required":true,"clause":"MADE-UP 6","source":0},{"id":"scalebar","label":"Graphic scale bar on every sheet (MADE-UP)","required":true,"clause":"MADE-UP 7","source":0}],"note":"MADE-UP teaching sample.","penTable":{"ref":"MADE-UP pen table: three weights, 0.13 / 0.25 / 0.5 mm","clause":"MADE-UP 5","source":0}},"notes":{"sources":[{"title":"MADE-UP: no real source","url":"https://example.com/made-up","fetched":"2026-11-11","licence":"Invented for teaching."}],"items":[{"id":"gen-dimensions","region":"sample","discipline":"general","title":"Dimensions govern","text":"Do not scale the drawings. Written dimensions govern. Verify all dimensions on site before work starts and report differences to the designer.","clause":"MADE-UP G1","source":0},{"id":"gen-codes","region":"sample","discipline":"general","title":"Codes in force","text":"All work is to follow the codes and rules in force at the place of the building and the requirements of the approving authority.","clause":"MADE-UP G2","source":0},{"id":"gen-coord","region":"sample","discipline":"general","title":"Coordination","text":"The contractor coordinates the trades and checks these drawings against the engineers' drawings before ordering.","clause":"MADE-UP G3","source":0},{"id":"arch-fire","region":"sample","discipline":"architectural","title":"Fire-rated penetrations","text":"Seal every penetration of a fire-rated wall or floor with a system suited to that rating.","clause":"MADE-UP A1","source":0},{"id":"arch-finish","region":"sample","discipline":"architectural","title":"Finishes","text":"Finishes are shown for design intent; confirm selections with the owner before ordering.","clause":"MADE-UP A2","source":0},{"id":"str-verify","region":"sample","discipline":"structural","title":"Structure by the engineer","text":"Structural members are sized by the engineer's drawings; this sheet shows layout only.","clause":"MADE-UP S1","source":0},{"id":"elec-code","region":"sample","discipline":"electrical","title":"Electrical layout","text":"Outlet and light positions are indicative; the electrical contractor lays out circuits to the applicable code.","clause":"MADE-UP E1","source":0},{"id":"plumb-test","region":"sample","discipline":"plumbing","title":"Testing","text":"Pressure-test drainage and supply pipework and keep the test record for the inspector.","clause":"MADE-UP P1","source":0}]}},"source_attrs":{},"license":{"id":"CC0-1.0","holder":"CadCraft","attribution":"“MADE-UP sample: drawing conventions and standard notes” by CadCraft (https://example.com/made-up), CC0 (https://creativecommons.org/publicdomain/zero/1.0/)","url":"https://creativecommons.org/publicdomain/zero/1.0/"},"provenance":{"library":"librarycraft","item":"a9586376-567b-4521-9619-5f373f5cbf78","version":1,"sha256":"72048e35f622aa6489827069a476e530a1bcc4951922c0606cf53da78327997a","source_file":"us-sample-practice.json","source_sha256":"8ad593e4a5bbc41cac6c942cd94fcbc45096dd53a492d2d744ce255fc47a6dd6","published_at":"2026-11-17T04:26:21Z"}}