Building regulations: Building regulations
India: Model Building Bye-Laws 2016 (TCPO, Ministry of Housing and Urban Affairs)
Front faces down the page. Dashed lines are hidden or above; dotted lines are door swings and clearances.
- Category
- Building regulations: Building regulations
- Kind
- Regulation pack
- Languages
- None provided. The words are as the provider wrote them.
- Author
- CadCraft
- Version
- 3, published Oct 27, 2026 Published
A model: states and cities issue the binding bye-laws, often based on it, and numbers vary by city. NBC 2016 was withdrawn on 2026-04-30 (replaced by the voluntary NBCS 2026). Light: 1/10 in hot-dry climates (1/6 warm-humid, 1/8 intermediate, 1/12 cold). The handrail rule has only a minimum (900), so it is not checked. Not checked by this pack: handrail height. Room size, hallway, egress door and…
License
CC0CC0 1.0 (public domain dedication). Anyone may use, change and share it for any purpose, with no conditions. Credit is welcome but not required.
The credit line for this version. Select it and copy it into your drawing or sheet notes.
Placing items works in the CadCraft and BimCraft apps, which are not open here yet. Download item.json to keep a copy.
Regulation pack
Draft: entered from the published code, not yet reviewed by a professional. A model: states and cities issue the binding bye-laws, often based on it, and numbers vary by city. NBC 2016 was withdrawn on 2026-04-30 (replaced by the voluntary NBCS 2026). Light: 1/10 in hot-dry climates (1/6 warm-humid, 1/8 intermediate, 1/12 cold). The handrail rule has only a minimum (900), so it is not checked. Not checked by this pack: handrail height. Room size, hallway, egress door and…
- Place
- India
- Pack id
in-mbbl-2016- Edition
- Model Building Bye-Laws 2016 (TCPO, Min…
- Authority
- Model code
- Source date
- 2016
- Last checked
- 2026-10-27
- Source
- TCPO / Ministry of Housing and Urban Affairs, Model Building Bye-Laws 2016 (TCPO, Ministry of Housing and Urban Affairs)
| Rule | Clause | Required |
|---|---|---|
| Riser height Residential buildings; at most 12 risers per flight. | MBBL 4.17.4.1 | At most 190 mm |
| Tread depth (going) Without the nosing. | MBBL 4.17.3 | At least 250 mm |
| Stair width Residential dwellings; 750 for two-storey row housing. | MBBL 4.17.2 | At least 1,000 mm |
| Stair headroom | MBBL 4.17.4.2 | At least 2,200 mm |
| Ceiling height Floor to the lowest point of the ceiling; at least 2400 under beams. | MBBL 4.3.1.1 | At least 2,750 mm |
| Glazing, share of floor area Openings excluding doors; climate values in 4.30.1.1. | MBBL 4.30.1.2 | At least 10 % of the floor area |
| Openable area, share of floor area The same openings give light and air; only the openable part counts. | MBBL 4.30.1.1 Note 1 | At least 10 % of the floor area |
A guide only: the registered professional and the local authority decide. A pack holds numbers and clause numbers, never the standard's text. The Building regulations add-on in BimCraft checks drawings against it.
Versions
All versions| Drawing | Version | Change | License | Status | Published |
|---|---|---|---|---|---|
| Version 3 | DataUpdated from the add-on's pack (d21568824556). | CC0 | Published | Oct 27, 2026 | |
| Version 2 | DataUpdated from the add-on's pack (bf3a0d312568). | CC0 | Published | Oct 27, 2026 | |
| Version 1 | GeometryFirst version, from the Building regulations add-on's pack. | CC0 | Published | Oct 27, 2026 |