Building regulations: Building regulations
Indonesia: PP 16/2021 Bangunan Gedung (stairs) and PP 12/2021 Perumahan (rumah tapak)
Front faces down the page. Dashed lines are hidden or above; dotted lines are door swings and clearances.
- Category
- Building regulations: Building regulations
- Kind
- Regulation pack
- Languages
- None provided. The words are as the provider wrote them.
- Author
- CadCraft
- Version
- 3, published Oct 27, 2026 Published
National law; local Perda add rules and handle permits. Room values are for landed houses (rumah tapak). Stair width is set only for exit stairs, headroom was not found, and handrails are a pair at 650 and 800 mm, so those are not checked. Not checked by this pack: stair width, stair headroom, handrail height. Room size, hallway, egress door and escape-opening rules have not been researched for t…
License
CC0CC0 1.0 (public domain dedication). Anyone may use, change and share it for any purpose, with no conditions. Credit is welcome but not required.
The credit line for this version. Select it and copy it into your drawing or sheet notes.
Placing items works in the CadCraft and BimCraft apps, which are not open here yet. Download item.json to keep a copy.
Regulation pack
Draft: entered from the published code, not yet reviewed by a professional. National law; local Perda add rules and handle permits. Room values are for landed houses (rumah tapak). Stair width is set only for exit stairs, headroom was not found, and handrails are a pair at 650 and 800 mm, so those are not checked. Not checked by this pack: stair width, stair headroom, handrail height. Room size, hallway, egress door and escape-opening rules have not been researched for t…
- Place
- Indonesia
- Pack id
id-pp16-pp12-2021- Edition
- PP 16/2021 Bangunan Gedung (stairs) and…
- In force from
- 2021-02-02
- Authority
- Adopted law
- Source date
- 2021-02-02
- Last checked
- 2026-10-27
- Source
- Pemerintah Republik Indonesia; Kementerian PUPR Ditjen Cipta Karya, PP 16/2021 Bangunan Gedung (stairs) and PP 12/2021…
| Rule | Clause | Required |
|---|---|---|
| Riser height Riser 150-170 mm; at most 12 steps per landing. | PP 16/2021 Lampiran, Tangga | At most 170 mm |
| Tread depth (going) | PP 16/2021 Lampiran, Tangga | At least 300 mm |
| Ceiling height Rumah tapak. | PP 12/2021 Lamp. I.A.2.b | At least 2,700 mm |
| Glazing, share of floor area | PP 12/2021 Lamp. I.A.3.b.2 | At least 10 % of the floor area |
| Openable area, share of floor area Cross-ventilation openings. | PP 12/2021 Lamp. I.A.3.a.1 | At least 5 % of the floor area |
A guide only: the registered professional and the local authority decide. A pack holds numbers and clause numbers, never the standard's text. The Building regulations add-on in BimCraft checks drawings against it.
Versions
All versions| Drawing | Version | Change | License | Status | Published |
|---|---|---|---|---|---|
| Version 3 | DataUpdated from the add-on's pack (07d39a22a2b4). | CC0 | Published | Oct 27, 2026 | |
| Version 2 | DataUpdated from the add-on's pack (ceab2b6c8ce0). | CC0 | Published | Oct 27, 2026 | |
| Version 1 | GeometryFirst version, from the Building regulations add-on's pack. | CC0 | Published | Oct 27, 2026 |
Make a copy and change it
Sign in to copy this item into your own library. The copy keeps a "Based on" link and credit to this one.
Report a problem
Wrong sizes, copied work, something that isn't a library item: tell us. Copyright holders can also write through the support form. How we handle it is on the rules page.