Building regulations: Building regulations

Wisconsin: Wisconsin Uniform Dwelling Code (UDC)

United States · WisconsinWisconsin: Wisconsin Uniform Dwelling Code (UDC)Wisconsin Uniform Dwelling Code (UDC)8 rules · Draft
ViewPlan
Version3
Overall15
ScaleFitted

Front faces down the page. Dashed lines are hidden or above; dotted lines are door swings and clearances.

Category
Building regulations: Building regulations
Kind
Regulation pack
Languages
None provided. The words are as the provider wrote them.
Author
CadCraft
Version
3, published Oct 27, 2026 Published

The state's own code, not based on the IRC: every number is its own (Wisconsin Dept. of Safety and Professional Services (DSPS); Wis. Admin. Code chs. SPS 320-325). Entered 2026-10-27 (research confidence: high); not yet reviewed by a professional.

License

CC0

CC0 1.0 (public domain dedication). Anyone may use, change and share it for any purpose, with no conditions. Credit is welcome but not required.

Read the license

The credit line for this version. Select it and copy it into your drawing or sheet notes.

Placing items works in the CadCraft and BimCraft apps, which are not open here yet. Download item.json to keep a copy.

Regulation pack

Draft: entered from the published code, not yet reviewed by a professional. The state's own code, not based on the IRC: every number is its own (Wisconsin Dept. of Safety and Professional Services (DSPS); Wis. Admin. Code chs. SPS 320-325). Entered 2026-10-27 (research confidence: high); not yet reviewed by a professional.

Place
United States (state: Wisconsin)
Pack id
us-wi
Edition
Wisconsin Uniform Dwelling Code (UDC)
Authority
Adopted law
Source date
2024-11
Last checked
2026-10-27
Source
Wisconsin Dept. of Safety and Professional Services (DSPS), Wis. Admin. Code chs. SPS 320-325
Rules in this pack (8)
RuleClauseRequired
Riser height
Spiral stairs 9.5 in.
SPS 321.04(2)(b)1.At most 203.2 mm
Tread depth
Rectangular treads.
SPS 321.04(2)(c)1.At least 228.6 mm
Stair width
Spiral stairs 26 in.
SPS 321.04(2)(a)At least 914.4 mm
Stair headroom
6 ft 4 in.
SPS 321.04(2)(d)1.At least 1,930.4 mm
Handrail height
Above the tread nosing.
SPS 321.04(3)(b)1.a.762 mm to 965.2 mm
Ceiling height
A room may be lower if at least half its floor area is 7 ft or more; beams may project 8 in below.
SPS 321.06At least 2,133.6 mm
Glazing, share of floor area
Exception for some basement, ground-floor and above-garage rooms other than bedrooms.
SPS 321.05(1)At least 8 % of the floor area
Openable area, share of floor area
Or balanced mechanical ventilation of at least 1 air change an hour.
SPS 321.05(2)(a)1.At least 3.5 % of the floor area

A guide only: the registered professional and the local authority decide. A pack holds numbers and clause numbers, never the standard's text. The Building regulations add-on in BimCraft checks drawings against it.

Versions

All versions
DrawingVersionChangeLicenseStatusPublished
United States · WisconsinWisconsin: Wisconsin Uniform Dwel…Wisconsin Uniform Dwelling Code (UDC)8 rules · Draft Version 3 DataUpdated from the add-on's pack (6490d407b459). CC0 Published Oct 27, 2026
United States · WisconsinWisconsin: Wisconsin Uniform Dwel…Wisconsin Uniform Dwelling Code (UDC)8 rules · Draft Version 2 DataUpdated from the add-on's pack (b50dacc5d1f1). CC0 Published Oct 27, 2026
United States · WisconsinWisconsin: Wisconsin Uniform Dwel…Wisconsin Uniform Dwelling Code (UDC)8 rules · Draft Version 1 GeometryFirst version, from the Building regulations add-on's pack. CC0 Published Oct 27, 2026

Make a copy and change it

Sign in to copy this item into your own library. The copy keeps a "Based on" link and credit to this one.

Report a problem

Wrong sizes, copied work, something that isn't a library item: tell us. Copyright holders can also write through the support form. How we handle it is on the rules page.

Report this item
For copyright: which work it copies and how you hold the rights.
We email you the outcome. Copyright reports from a signed-in account hide the files at once; others are queued for a person.