- 3, published Oct 27, 2026 Published
Adopts IRC 2018 (Indiana Fire Prevention and Building Safety Commission; 675 IAC 14-4.4 (LSA #19-330(F))). State amendments to the checked rules: riser height, tread depth. Amendments were researched for stairs, ceiling height, light and ventilation only; every other rule (room size, egress, escape openings, electrical, alarms) is the base code's. Entered 2026-10-27 (research confidence: high); n…
License
CC0CC0 1.0 (public domain dedication). Anyone may use, change and share it for any purpose, with no conditions. Credit is welcome but not required.
The credit line for this version. Select it and copy it into your drawing or sheet notes.
Placing items works in the CadCraft and BimCraft apps, which are not open here yet. Download item.json to keep a copy.
Regulation pack
Draft: entered from the published code, not yet reviewed by a professional. Adopts IRC 2018 (Indiana Fire Prevention and Building Safety Commission; 675 IAC 14-4.4 (LSA #19-330(F))). State amendments to the checked rules: riser height, tread depth. Amendments were researched for stairs, ceiling height, light and ventilation only; every other rule (room size, egress, escape openings, electrical, alarms) is the base code's. Entered 2026-10-27 (research confidence: high); n…
- Place
- United States (state: Indiana)
- Pack id
us-in- Builds on
- United States: International Residential Code 2018
- Edition
- IRC 2018 as adopted, 2019-12-26
- In force from
- 2019-12-26
- Authority
- Adopted law
- Source date
- 2019
- Last checked
- 2026-10-27
- Source
- Indiana Fire Prevention and Building Safety Commission, 675 IAC 14-4.4 (LSA #19-330(F))
| Rule | Clause | Required |
|---|---|---|
| Riser height State amendment. | 675 IAC 14-4.4-16 (R311.7.5.1) | At most 209.55 mm |
| Tread depth State amendment. | 675 IAC 14-4.4-17 (R311.7.5.2) | At least 228.6 mm |
A guide only: the registered professional and the local authority decide. A pack holds numbers and clause numbers, never the standard's text. The Building regulations add-on in BimCraft checks drawings against it.
Versions
All versions| Drawing | Version | Change | License | Status | Published |
|---|---|---|---|---|---|
| Version 3 | DataUpdated from the add-on's pack (7cc968395063). | CC0 | Published | Oct 27, 2026 | |
| Version 2 | DataUpdated from the add-on's pack (c0784f689c40). | CC0 | Published | Oct 27, 2026 | |
| Version 1 | GeometryFirst version, from the Building regulations add-on's pack. | CC0 | Published | Oct 27, 2026 |
Make a copy and change it
Sign in to copy this item into your own library. The copy keeps a "Based on" link and credit to this one.
Report a problem
Wrong sizes, copied work, something that isn't a library item: tell us. Copyright holders can also write through the support form. How we handle it is on the rules page.