Building regulations: Building regulations

Poland: Rozporządzenie w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie (Dz.U. 2022…

PolandPoland: Rozporządzenie w sprawie warunków techniczn…Rozporządzenie w sprawie warunków techn…5 rules · Draft
ViewPlan
Version2
Overall15
ScaleFitted

Front faces down the page. Dashed lines are hidden or above; dotted lines are door swings and clearances.

Category
Building regulations: Building regulations
Kind
Regulation pack
Languages
None provided. The words are as the provider wrote them.
Author
CadCraft
Version
2, published Oct 27, 2026 Published

Values for single-family houses (multi-family buildings: riser 175, width 1200, balustrade 1100). STATUS: ISAP lists this regulation as repealed from 2026-09-21; under the transition rules (Dz.U. 2026 poz. 1161) investors may design and build to it for 18 months (to about March 2028). No replacement found as of 2026-10-27. The going is a formula (2h + s = 600-650 mm) and the balustrade has only a…

License

CC0

CC0 1.0 (public domain dedication). Anyone may use, change and share it for any purpose, with no conditions. Credit is welcome but not required.

Read the license

The credit line for this version. Select it and copy it into your drawing or sheet notes.

Placing items works in the CadCraft and BimCraft apps, which are not open here yet. Download item.json to keep a copy.

Regulation pack

Draft: entered from the published code, not yet reviewed by a professional. Values for single-family houses (multi-family buildings: riser 175, width 1200, balustrade 1100). STATUS: ISAP lists this regulation as repealed from 2026-09-21; under the transition rules (Dz.U. 2026 poz. 1161) investors may design and build to it for 18 months (to about March 2028). No replacement found as of 2026-10-27. The going is a formula (2h + s = 600-650 mm) and the balustrade has only a…

Place
Poland
Pack id
pl-warunki-techniczne-2002
Edition
Rozporządzenie w sprawie warunków techn…
In force from
2002-12-16
Authority
Adopted law
Source date
2022-04-15
Last checked
2026-10-27
Source
Minister Infrastruktury (now Minister Rozwoju i Technologii), Rozporządzenie w sprawie warunków technicznych, jakim pow…
Rules in this pack (5)
RuleClauseRequired
Riser height
Single-family and farm houses, two-level apartments; 175 mm in multi-family buildings.
§ 68 ust. 1At most 190 mm
Stair width
Usable width between handrails, single-family; 1200 multi-family.
§ 68 ust. 1, ust. 4At least 800 mm
Ceiling height
Rooms in residential buildings; 2200 for attic rooms in single-family houses (average height under sloped ceilings).
§ 72 ust. 1At least 2,500 mm
Glazing, share of floor area
Window clear frame opening at least 1:8 of the floor area.
§ 57 ust. 2At least 12.5 % of the floor area
Openable area, share of floor area
At least 50 % of the required window area opens (without mechanical ventilation).
§ 155 ust. 1At least 6.25 % of the floor area

A guide only: the registered professional and the local authority decide. A pack holds numbers and clause numbers, never the standard's text. The Building regulations add-on in BimCraft checks drawings against it.

Versions

All versions
DrawingVersionChangeLicenseStatusPublished
PolandPoland: Rozporządzenie w sprawie …Rozporządzenie w sprawie warunków techn…5 rules · Draft Version 2 DataUpdated from the add-on's pack (e1067aaab5f8). CC0 Published Oct 27, 2026
PolandPoland: Rozporządzenie w sprawie …Rozporządzenie w sprawie warunków techn…5 rules · Draft Version 1 GeometryFirst version, from the Building regulations add-on's pack. CC0 Published Oct 27, 2026

Make a copy and change it

Sign in to copy this item into your own library. The copy keeps a "Based on" link and credit to this one.

Report a problem

Wrong sizes, copied work, something that isn't a library item: tell us. Copyright holders can also write through the support form. How we handle it is on the rules page.

Report this item
For copyright: which work it copies and how you hold the rights.
We email you the outcome. Copyright reports from a signed-in account hide the files at once; others are queued for a person.