Add-onsAdd-on for BimCraft
Fire sprinklers
Sprinkler heads on a grid in a room by hazard class, the branch lines and cross main that feed them, and a density/area hydraulic calculation (Hazen-Williams, K-factor heads, hose allowance, a water-supply test). The design criteria are your table; the defaults are labelled for professional review. A design aid, not an approval.
What it is allowed to do
- Adds commands
- Adds a panel section
- Opens or saves its own file types
- Keeps its own settings in this browser
An add-on runs inside the app with the app's own access to the page. That is why only add-ons the CadCraft team has read, reviewed and signed can be added from here; the apps check the signature again before they load one.
Add
Adding needs JavaScript in this browser. You can still download the signed package.
Add-ons you added work in the browser apps on this computer, offline too. They load when the app starts: reload an open app after adding one. Turn one off any time in the app's Settings, under General. The desktop app will add from here too; that is not built yet.
Versions
| Version | Published | State | Size |
|---|---|---|---|
| 0.8.0 | November 9, 2026 | Reviewed and signed | 252 KB |