FeatureBuilt · in the lab

Fields

Wire antennas, eddy currents, capacitance, motor, transformer and generator sheets, cooling, a 3-D full-wave solver, a board in a metal enclosure, surge and discharge waveforms and magnet rotors in 3-D, each checked against a formula.

Use this add-on:

Lab

Screenshots and a short video come with the listing (AL.3).

Overview

Fields puts seven electrical field calculators in one tab. Wire antennas are solved by the method of moments: feed impedance, match to your line, gain and the radiation pattern for a dipole, a monopole, a folded dipole, a three-element Yagi or an inverted V. Eddy currents and skin effect are solved on a cross-section for a round wire, a bar or a pair of bars. Capacitance per meter comes from a flat electrostatic solution, with the full capacitance matrix for traces over a ground plane.

Three design sheets give a first sizing of a permanent-magnet motor, an induction motor and a transformer, and a thermal network estimates the temperatures of an enclosure or a board in still air or with a fan. Where a textbook formula exists for your case, the result shows it beside the calculation with the difference. It is an aid for early design, not an approval.

Round two adds six more. A three-dimensional full-wave solver (finite differences on a Yee grid with absorbing layers) rings an empty metal box and radiates from a short dipole, and shows its answers against the closed forms. The same solver puts a board stub inside a thin metal box with a slot and reports the shielding at a point outside, which by reciprocity is also the weak spot for an incoming field. A surge sheet gives the standard lightning and discharge waveforms, the voltage they induce in a loop beside a wire and the stress on a protective clamp. A magnet rotor in 3-D finds the flux linkage and back voltage of block magnets turning past a coil, with no iron. A generator sheet works a three-phase synchronous machine from its reactance or from the open and short circuit tests. A comparison tool sets a measured curve against a calculated one.

Who it’s for

  • An electronics or power engineer who wants a quick, checked number before opening a full simulation.
  • A radio amateur or antenna hobbyist sizing a wire antenna and its match.
  • A machine designer doing a first sizing of a motor or a transformer.
  • A student who wants to see a formula and a numerical solution agree.

What you can do

  • Solve a wire antenna by the method of moments: feed impedance, standing wave ratio, return loss, directivity, gain, two pattern cuts, impedance across a band and the resonance. verified
  • Offer five ready shapes: straight dipole, monopole over a perfect ground, folded dipole, three-element Yagi, inverted V. verified
  • Solve eddy currents at one frequency in a round wire, a rectangular bar or two bars: skin depth, resistance ratio, loss per meter, internal and loop inductance, and a picture of the current density. verified
  • Solve flat electrostatics: coaxial line, parallel plates with one or two layers and optional edge field, one to four traces over a ground plane with the capacitance matrix, line impedance and effective permittivity. verified
  • Size a surface permanent-magnet motor: gap flux density, back EMF, torque constant, torque, loading, copper loss, efficiency. verified
  • Work an induction motor from its equivalent circuit: current, power factor, power flow, torque, efficiency, the torque against speed curve, starting and pull-out torque. verified
  • Work a transformer from its open-circuit and short-circuit tests (regulation, efficiency) or size one from the core (turns, wire, losses, area product). verified
  • Estimate enclosure and board temperatures by a thermal network with natural convection, forced air and radiation. verified
  • Show each result beside a textbook formula where one exists, and save figures and curves as CSV.
  • Solve Maxwell's equations in 3-D in the time domain on a Yee grid with absorbing layers: ring an empty metal box and read its resonances, radiate from a short dipole and read the power through a closed surface. verified
  • Put a board stub in a thin metal enclosure with a slot and read the shielding at a point outside, across a frequency range, beside the slot rule of thumb. verified
  • Draw the lightning voltage impulse, the surge current, the lightning current and the discharge current at your peak, with the induced loop voltage and the clamp energy. Every value is marked not checked against the standard. verified
  • Find the field of block magnets in 3-D, the flux linkage of a coil as the rotor turns, the back voltage and its harmonics, in air with no iron. verified
  • Work a three-phase synchronous generator: field voltage, load angle, regulation, losses, efficiency, torque and the power limit, and the external curve. verified
  • Set a measured curve beside a calculated one: bias, RMS and largest difference, correlation and the share of points within your tolerance.

Methods and standards

Antennas: thin-wire electric-field integral equation, Galerkin method of moments with triangle basis functions, a perfect ground by images. Eddy currents and capacitance: linear-triangle finite elements on a cross-section with a banded direct solver; conductor currents are enforced as totals, capacitances are read from the reactions at the conductors. Machine sheets: magnetic circuit of a magnet and a gap, the EMF equation, per-phase equivalent circuits, the open-circuit and short-circuit tests, the area-product method. Cooling: a network of conductances solved again until the temperature-dependent coefficients settle, with published correlations for plates in still and moving air. Every formula names its textbook or paper in the engine's code.

3-D solver: the Yee scheme in 64-bit numbers, leapfrog in time at 0.99 of the Courant limit, convolutional absorbing layers with polynomial grading, thin metal plates as zero tangential field, lumped current sources, probes and a closed-surface power monitor from running Fourier sums. Enclosure: the same solver run twice, with and without the box. Surge: double exponentials and Heidler functions fitted to the stated times, the discharge current fitted to its four numbers, the mutual inductance of a wire and a loop. Magnets: surface-pole integrals over each block face by Gauss quadrature and the closed form for a finite wire. Generator: the per-phase circuit with a complex solution. The solver's API is documented at the top of lib/emfields/fdtd3d.js, so other tools can call it.

Data and sources

The add-on ships no material library and no standard's tables. Copper's resistivity and its temperature coefficient, the air property formulas and the physical constants are in the code with their sources. The example inputs of the induction motor and transformer sheets are the worked examples of a standard machines textbook, quoted from memory and reproduced by the calculation; the convection correlations are cited by author and chapter and were not re-read for this release. Everything else is what you type. The surge sheet carries its waveform numbers marked as not checked against the standards; no maker data is bundled.

Verification

CaseResult
Half-wave dipole against the textbook valuesA thin half-wave dipole (radius one hundred-thousandth of a wavelength) comes out within 3 percent of 73.1 ohms, within 2 ohms of 42.5 ohms reactance and within 1 percent of directivity 1.643, with radiated power equal to input power (bin/test-emfields.mjs)
Skin effect against closed formsThe field entering a conducting slab matches the exact hyperbolic-sine profile, and a round copper wire's resistance ratio and internal inductance match the Bessel-function formula within 0.5 percent from zero frequency to five skin depths (bin/test-emfields.mjs)
Capacitance against closed formsA coaxial line is within 0.5 percent of 2 pi epsilon over ln(b/a), plates without edges equal epsilon w over d for one and two layers, three coaxial cylinders give the exact 2 by 2 matrix within 0.5 percent, and every matrix is symmetric (bin/test-emfields.mjs)
Motor and transformer sheets against worked examplesThe induction motor sheet reproduces the worked 460 V four-pole example (18.88 A, 0.833 power factor, 62.8 N·m, 83.7 percent), the transformer sheet reproduces the worked 20 kVA test example, and the permanent-magnet torque equals the sizing equation (bin/test-emfields.mjs)
Thermal network and correlationsA two-resistor network matches hand calculation, the vertical-plate correlation reproduces a worked textbook case (Nusselt number 147 at a Rayleigh number of 1.81e9), air properties at 300 K are within 1 percent of table values, and heat leaving equals heat released (bin/test-emfields.mjs)
3-D full-wave solver against closed formsA metal box rings within 0.6 percent of the closed-form resonances and within 0.04 percent of the exact grid dispersion relation, a short dipole radiates within 3 percent of the textbook power and the same power through two different surfaces, the absorbing layer leaves under 1 percent against a lar
Surge waveforms and couplingThe front and half-value times of three impulses are reproduced to 1e-6, the discharge current matches its four numbers within 1 percent, the integrals match closed forms and the mutual inductance matches the Neumann double integral within 1 percent. The waveform numbers themselves are not checked a
Magnet field and rotor against closed formsA current loop matches its on-axis formula, a long wire matches mu0 I over 2 pi r, a block magnet matches the published on-axis closed form to 1e-5 and a far cube is a dipole, and the flux linkage of alternating poles reverses after half a cycle with only odd harmonics (bin/test-fdtd3d.mjs)
Generator sheet identitiesThe power balance closes exactly, the power limit equals a sweep of the load angle, and the terminal voltage is recovered from the internal voltage and the current (bin/test-fdtd3d.mjs)
In a real browserIn PartCraft in the lab the add-on is switched on, each of the thirteen calculators is run, the figures and checks are read from the page and a CSV file is saved, with no console errors (tools/emfields/browser.mjs)

Limits

This is a design aid, not an engineering approval: it does not replace the judgement, the checks and the sign-off of the person responsible for the work, and nothing you build from its figures should rest on it alone.

- Antennas: perfect conductors, perfect or no ground, thin wires, five ready shapes. No real earth, insulation, loads or matching networks in the panel. - Eddy currents: long straight conductors, one frequency, constant permeability, three ready arrangements. Not your own sketch yet. - Capacitance: flat cross-sections with rectangular conductors on a grid. Up to four traces. - Machine sheets: no saturation, no slot or tooth detail, no demagnetization check, no temperature rise, no standards check. - Cooling: each node is one temperature. No hot spots, no flow pattern, no altitude correction, no solar load. - Runs in PartCraft in this release. It does not read or change the part. - Not compared with any other program. An aid, not an approval. - 3-D solver: cubic cells, staircase edges, perfect metal, no dispersive materials, absorbing layers about 60 dB at right angles. Small grids only (the browser holds the whole grid in memory and runs on one thread). Frequencies are as sharp as the run is long. - Enclosure: walls infinitely thin, a one-cell slot, a current stub for the board, near field at one point. Not a test result and not a pass mark. - Surge: names and numbers written from memory of the standards and NOT checked against them; the discharge current between its four specified numbers is a fit made here. - Magnet rotor: no iron, so no machine with steel; block magnets alternating radially; one coil. - Generator: round rotor, one reactance, no saturation. - Measured comparison: this tool gives numbers; a person decides whether the model is good enough. A comparison with real measurements has not been done (see the hand-check document).

Files and formats

Saves a CSV file of the figures, the checks and the plotted curves of the calculator on screen. It reads no files and writes nothing into the part.

Get started

  1. Switch the add-on on in Settings, Add-ons, then open the Fields tab.
  2. Pick a calculator, keep the example or type your own values, and press Calculate.
  3. Read the figures and the check against the textbook formula, then look at the pictures.
  4. Save as CSV to keep the result.

Languages

The text is available in:

  • English (en)

Works in

EditionWorksNote
Browser (/use) (yours) Added on demand Fetched the first time you use it, then kept for offline use.
Studio from getcadcraft.com Added on demand Fetched the first time you use it, then kept for offline use.
Microsoft Store Added on demand Fetched the first time you use it, then kept for offline use.
Google Play Added on demand Fetched the first time you use it, then kept for offline use.
iPad and iPhone (App Store) Included; switch it on Part of the reviewed app; your list switches it on.
Custom build Added on demand Fetched the first time you use it, then kept for offline use.

Comes with

Nothing else.

Versions

VersionChannelDateWhat changed
1.0.0labNovember 25, 2026First version in the Library.

Licence and maker

CadCraft (CadCraft, first-party). Licence: Apache-2.0. Dependencies carry their own licences, listed on their pages.