DC.133 DetailCraft: export for Zeman machines (NC files plus an XML file)
Asked (Discord #detailcraft, 2026-11-14; follow-up 2026-11-16; sample set sent on /suggest #1972, 2026-11-18): Zeman export beside the DSTV export. Built in /lab 2026-11-19 as an off-by-default add-on "Zeman export": Output > NC files asks Zeman (XML + NC) or DSTV; per assembly a folder <mark> with <mark>.Xml (WIA 1.0: HEAD, ASSEMBLY of PART with FRAME BASE/RX/RY and a DSTV-NC REFERENCE) and the NC files, zipped; identical plates share a file. Built only from the requester's one sample (testfiles/zeman-sample-1972, never in a repo): her XML read and written back is byte-identical; the frame convention was fixed against her reference IFC and reproduces her numbers for all 8 parts. Limits: I-shape main parts with plates only (others refused with the reason); no weld information; always mm; our NC files differ from hers in layout (no reference letters, plate header columns, no REALGEWICHT line, round holes only). No Zeman software has read our output: see DC.133-HAND. Not done: help topic, listing, languages, catalogue seed/package/sign. Tests: tools/detailcraft-test/test-zeman.mjs 77/0, browser-zeman.mjs 17/0. Log: docs/0.10.1.md 101.35.
Lab pass 133 (2026-11-19/20): ProFit3D 24.1.1030.1286 refused the XML ("error on line 2 at column 2"): line 2 was the sample's "<>". With the Zeman tool's comment line written there by hand it imported. Fixed in a Discord member as FX.397.