Roadmap 0.11, Fixes

FX.373 DetailCraft foundation: a footing shear Vy shifted the soil pressure the wrong way (detailcraft#4)

  • Fix
  • Built · in the lab
  • DetailCraft

detailcraft#4: in foundation.js checkFooting the base moment from a horizontal force Vy applied h above the footing base had the wrong sign (Mx_base = Mx - h*Vy, so ey = (sum P*y - Mx + h*Vy)/N; the code had - h*Vy). It shifted the soil pressure toward -y, under-reporting bearing and over-reporting the overturning factor of safety when Vy and its own Mx act together. Fixed in the service eccentricity (ey), the factored one (eyu) and the y-cut section moments (cutY); the x lines were right. Hand check (reporter's footing 2895.6 x 2286 x 762 mm): Vy alone e = h*Vy/N toward +y, same size as Vx toward +x; Vy = 8.8964 kN with Mx = -24.4047 kN.m gives a base moment 24.405 + 0.762*8.8964 = 31.18 kN.m, e = 31.18/N. A square footing with Vx only (x cut) and Vy only (y cut) now gives the same Mu. Log: tools/detailcraft-test/test-foundation.mjs 57/0. Log: docs/0.10.1.md 101.17.

Add a comment

Community comments

No comments yet

Add detail as we go: how you would use it, files or steps that show the problem, what other programs do. The team reads every comment.

Sign in or create a free account to add a comment.