Roadmap 0.11, California 2025 codes: energy code check and Title 24 (Track T24)

T24.3 Energy code check in BimCraft: reads walls, windows and their compass directions from the model

  • Feature
  • Built · in the lab
  • BimCraft

Built in /lab 2026-11-20 (BimCraft a Discord member, right-panel tab Energy code check). The adapter reads the exterior wall types with their net areas and guesses the framing from the stud layer, each window and door in an exterior wall with its area and the compass bearing its wall faces (from the site's true north), the floor area inside the outside faces, and the postal code when the file has one. What the model cannot say (cavity and continuous insulation, attic and floor insulation, the windows' rated values) the person states; it is kept in the drawing as CadCraft_EnergyCode on the project, quick changes as one undo step. The check saves as CSV. Test: tools/energy-code/browser.mjs 20 of 20 on the Hillside ranch in the real lab page. What it found on that house in zone 13: the stucco 2x6 wall with R-21 is U 0.069 against the package's 0.048 (R-5 continuous insulation brings it to 0.048); the twelve windows are 10.9 % of the floor area (20 % allowed) but the west-facing ones are 6.1 % against 5 %. Not built: results in the Problems panel, the other apps, a level turned against the model's axes (wrong directions), Undo of the stated values was not driven in the browser test.

Add a comment

Community comments

No comments yet

Add detail as we go: how you would use it, files or steps that show the problem, what other programs do. The team reads every comment.

Sign in or create a free account to add a comment.