Roadmap 0.11, California 2025 codes: energy code check and Title 24 (Track T24)

T24.6 Quick heat loss: use the wall's real U-factor (insulated framing, not a solid wood stud layer)

  • Feature
  • Built · in the lab
  • BimCraft

The owner's list of the quick loads' weak points, 2026-11-20: the stud layer is read as solid wood; the roof and floor have no insulation layers; sun through the windows is not in the cooling figure; outside temperatures came from memory (done: WX.2). Built in the lab for WALLS: in the Energy code check, each exterior wall type whose framing, spacing and insulation are stated gets a button, "Use U x W/m2K in the heat loss", that writes the code table's U-factor (JA4 Table 4.3.1, no interpolation) into the type's exterior walls as Pset_WallCommon.ThermalTransmittance, one undo step, which Heating and cooling loads read before the layers. 2x6 R-21 at 16 in.: 0.069 Btu/h.ft2.F = 0.3918 W/m2K; with R-5 continuous 0.048 = 0.2726. Not done: ceiling and floor (no floor table in the pack; the attic table is not mapped to the roof element); the sun in the cooling figure still needs the Daylight tab's sun step run first, and the panel says so.

t24-6-envelope 2026-11-22: CEILING and FLOOR built. Energy code check add-on 0.11.1: a vented attic's U-factor from JA4 Table 4.2.1 (page JA4-11; R-38 at 24 in. = 0.025 = 0.142 W/m2K), a raised wood floor's from Table 4.4.1 over a vented crawl space (JA4-70; 2x8 R-19 = 0.037 = 0.2101) or 4.4.2 with outside air under it (JA4-72), each with a button that writes it into the roof elements (IfcRoof, slabs typed ROOF) or the lowest level's floor slabs, one undo step; a slab on the ground shows its F-factor per foot of edge (Tables 4.4.7 / 4.4.8, JA4-82 / JA4-83) and is not written as a U-factor. SUN: Heating and cooling loads now work out the sun through the windows themselves (the Daylight tab's clear-sky method, its date and g-value) when the model has a site. bin/test-energy-code.mjs 123/0; tools/energy-code/browser.mjs 36/0 in the real lab page (Hillside ranch: 5 roof elements at 0.142, 14 floor slabs at 0.2101, sun 1,677 W in the first room).

Waits on: A person trying it on a real house (the loads, the table figures, the sun)

Add a comment

Community comments

No comments yet

Add detail as we go: how you would use it, files or steps that show the problem, what other programs do. The team reads every comment.

Sign in or create a free account to add a comment.