Roadmap 0.11, Fixes
FX.395 BimCraft EnergyPlus file: true north was always written as 0
Found 2026-11-20 the same way. The file's surfaces are in the model's own axes, but the Building's North Axis was always 0, so a model whose true north is not up the page had the sun on the wrong sides in EnergyPlus. The Hillside ranch's true north is along -x: its file now says 90, and an outside viewer reads "North axis: 90". Fixed in energy-ep.js idfFromModel from the site's true north. bin/test-bimcraft.mjs --ops --only idf (6) still passes; no unit test was added for a turned model, and no EnergyPlus run was made to compare.