Roadmap 0.11, Chemical and process engineering (Track CH)
CH.38 Water treatment: chemical dosing (phosphorus precipitation, alkalinity, disinfection dose)
Found by chem-finish-11: no dosing. Add dose calculations from stoichiometry: iron or aluminium salt for phosphorus removal (molar ratio as an input), alkalinity used by nitrification and lime or caustic to restore it, chlorine dose from demand and residual; daily chemical mass and volume.
Community comments
No comments yet
Add detail as we go: how you would use it, files or steps that show the problem, what other programs do. The team reads every comment.
Sign in or create a free account to add a comment.