Roadmap 0.11, Chemical and process engineering (Track CH)

CH.39 Water treatment: reproduce the published BSM1 benchmark (steady state)

  • Feature
  • Built · in the lab
  • CivilCraft
  • SuperCad Studio

Found by chem-finish-11: the ASM1 calculator has never been compared with the published benchmark. Build the BSM1 plant (five reactors, internal and sludge recycle, the ten-layer settler of CH.33) from the BSM1 description (Alex et al., IWA Benchmark Simulation Model no. 1) and compare the steady-state results with the published table; the test pins the numbers.

Waits on: An engineer looks over the comparison: 112 of 112 published BSM1 steady-state values within max(0.1 %, 0.001 g/m3). Check: CH.39-HAND.

Add a comment

Community comments

No comments yet

Add detail as we go: how you would use it, files or steps that show the problem, what other programs do. The team reads every comment.

Sign in or create a free account to add a comment.