Roadmap 0.11, Interior lighting design add-on (IL)
IL.7 Lighting design: windows and daylight, emergency lighting, obstruction by furniture and walls, isolines, 3D view
The DIALux-class features not built: daylight factor and sky, escape-route lighting (EN 1838), visibility so partitions and furniture block light, isolines, luminaire selection from a maker catalogue, exterior and road lighting.
adapters-09 2026-11-06: Built and tested: windows and a daylight factor under the CIE overcast sky (sky law checked by hand: full sky 100 % of Eext, an endless vertical window 50 %, vertical plane 0.396; the light entering a room equals T x Ev x glass area to 0.15 %), boxes that block direct light, and an emergency lighting check on an escape route and the open area (limits unverified, labelled as waiting for a lighting engineer). No sun, ground reflection or outside obstructions; nobody has compared a room with another program. lib/lightdesign/test/test.mjs 97/0.
light-11 2026-11-20: isolines (marching squares on the result grid, labelled on the map and in the report; every line point checked against the calculation within 3 %) and a 3D lux surface mesh (luxSurface: one vertex per grid point, height and colour) built and tested; obstruction and daylight were built in 0.9. The 3D mesh has no view in the panel yet. Emergency values stay unverified and claim no standard.
Community comments
No comments yet
Add detail as we go: how you would use it, files or steps that show the problem, what other programs do. The team reads every comment.