Roadmap 0.11, Fixes

FX.50 CivilCraft: empty table cells centred and light, Spiral In/Out under one Spiral header, road shown on the graded ground in 3D

  • Fix
  • Built · in the lab
  • CivilCraft

Owner screenshots 2026-11-05. (1) The dash in an empty table cell is centred and drawn light (civilcraft.js/.css). (2) The PI table has one Spiral heading over In and Out (keys cv.al.col.spiral/in/out; other languages fall back to English until translated). (3) 3D: with a corridor and only the existing ground shown, the road sank into hills; the graded surface now comes with it, existing ground see-through (site-view3d.js). The design profile of the sample drawing does not follow its ground (cuts and fills of 1-2 m), which is the drawing, not a bug. 3D suite 155/0; no browser check.

Verified 2026-11-20 (0.11 close-out): /lab/civilcraft, the sample site with an alignment, design profile and corridor. PI table: one 'Spiral' heading (colspan 3) over In, Out and To next (To next joined later, SU.1944); 9 empty cells show a centred dash (text-align center) in a light colour (ink at 45% alpha vs rgb(23,32,43)); no raw keys. 3D: meshes eg, fg, road; 36/36 sampled road points lie on the graded surface (max 0.000003 ft off), 28 are > 0.6 ft off the existing ground; existing ground see-through (opacity 0.45), graded solid. Script tools/verify-close-11/FX.50.mjs 10/0; table and 3D screenshots read.

From: owner

Add a comment

Community comments

No comments yet

Add detail as we go: how you would use it, files or steps that show the problem, what other programs do. The team reads every comment.