Roadmap 0.11, WaterCraft add-on (WN)

WN.11 WaterCraft calibration against field pressure and flow readings

  • Feature
  • Built · in the lab
  • CivilCraft

Built in the lab: roughness of groups of pipes (and a demand factor) fitted to pressure and flow readings by damped least squares; weak groups named; Apply writes the roughness (Undo). Reading logger or SCADA exports are WN.14. Tested in the real lab page (tools/waternet-engine/browser-11.mjs) with EPANET Example Network 1; help in the add-on (watercraft-scenarios, watercraft-studies). Text boxes (scenarios, rules, valves, readings) are not saved in the project file yet. Not listed in the Library until the owner runs the seed.

From: Discord community

Add a comment

Community comments

No comments yet

Add detail as we go: how you would use it, files or steps that show the problem, what other programs do. The team reads every comment.