Feature

Dome spec: Europe

The Europe spec for the Dome generator: cover, strength, steel and spacing from EN 1992-1-1 and what the EN standards say on shells and sprayed concrete, each with its clause and how it was read.

Use this add-on:

Sign in to add to every edition Also adds 1 item it needs (1.3 MB). Use offline Download as a file 84 KB
Dome generator panel showing the Europe spec rules with their Eurocode clauses beside the dome plan
Screenshot from the lab build. The Dome generator with the Europe spec in force: 31 rules read in the standards themselves, each with its Eurocode 2 clause (cover 15 mm, concrete at least C20/25).
Factored membrane forces table for the dome under the Europe spec
With the Europe spec the forces are factored (own weight × 1.35): the default 10 m dome carries 474.3 kN at the springline, 0.124 MPa largest compression.

Overview

This is the Europe spec for the Dome generator: a data pack of what the Eurocodes set for a thin concrete shell. Cover, the strength class, the minimum steel ratio and bar spacing come from EN 1992-1-1, read in its 2004 edition, as the recommended values that a national annex may change. What EN 1992-2 says on analysing shells, EN 14487 on sprayed concrete, EN 1991 on snow and wind, EN 13501-1 on fire classes and EN 1997-1 on frost is there to read. Switch it on and pick it in the Dome generator's Spec section: its values fill the boxes you left empty, and the design is checked against the ones it holds as numbers.

Every value names its standard and clause, and says whether we read it in the standard's own text, in a document that quotes it, or could not read it at all (then there is no value). EN 1992-1-1:2004 barely mentions shells: it gives no minimum thickness and no dome buckling rule, so the steel and spacing values are its slab rules. No sprayed concrete strength class was read. The snow standard read has no clause for domes. It is not a substitute for the standards or your national annex, and a licensed engineer must design and check the dome.

Who it’s for

To be written (AL.3): the people and the jobs this serves (docs/0.8-SOUND-SPEC.md § 2 shows the depth expected).

What you can do

  • Fill the Dome generator's empty boxes from the spec's values where it has one the generator can use.
  • See each rule with its standard, clause and how it was read, in the Dome generator's Spec section.
  • Get a row in the result, and in Problems, for every figure that breaks a value in the spec.
  • Read the rules the generator does not use as numbers (buckling, analysis, tension steel, bar spacing, sprayed concrete testing, loads, foam and fire, frost) beside the ones it does.
  • Fill the load factors for own weight, snow, wind and earthquake, so the forces, the bending and the uplift check are factored.
  • Bring the rules that most need a decision (buckling, foam and fire, wind and snow on domes, openings) up as notes under Checks.

Methods and standards

A rule is used by the generator only when its value is a number in the unit the generator works in; a strength class such as C20/25 is read as its cylinder strength. A minimum raises a starting figure; your own figure always stands and is reported when it breaks the rule. Rules that are sentences are shown, not applied. Standards: EN 1992-1-1:2004, EN 1992-2:2005 Annex LL, EN 14487-1 and EN 14487-2, EN 1991-1-3 and EN 1991-1-4, EN 13501-1, EN 13165 (which does not cover foam sprayed on site), EN 1997-1.

Data and sources

The pack is made from research done on 2026-11-20, kept in the source as tools/dome/research/eu.json: for every rule the value, the standard, the clause, the page it was read on and the sentence read. No value was typed from memory. Researched again on 2026-11-21. Of 35 rules, 31 were read in the standard's own text, 2 in documents that quote it, 2 not at all. The load factors are EN 1990's recommended values (1.35 on permanent actions, 1.0 where they help, 1.5 on the leading variable action, 0.75 on snow beside a leading wind). No Eurocode buckling formula for shells exists in the text read; the guidance shown is from a university dissertation describing the published reduction-factor method and the old German safety factor of 5. Every EN 1992-1-1 value is from the 2004 edition, not the 2023 one, and is a recommended value: your national annex may set another. Frost depth and the fire class required are national and were not read for any country. The cover against earth is the figure for prepared ground or blinding; concrete cast straight against soil has a larger one, given in the rule's note.

Verification

To be written (AL.3): benchmark cases and their results, linked to the verification manual (IND.1).

Limits

To be written (AL.3): what it does not do, and where its answers stop being good. Every engineering item says “a design aid, not an engineering approval”.

Files and formats

To be written (AL.3): what it reads and writes, and what it stores inside drawings.

Get started

To be written (AL.3): three steps and a sample file to open.

Languages

The text is available in:

  • English (en)

Works in

EditionWorksNote
Browser (/use) (yours) Added on demand Fetched the first time you use it, then kept for offline use.
Studio from getcadcraft.com Added on demand Fetched the first time you use it, then kept for offline use.
Microsoft Store Added on demand Fetched the first time you use it, then kept for offline use.
Google Play Added on demand Fetched the first time you use it, then kept for offline use.
iPad and iPhone (App Store) Included; switch it on Part of the reviewed app; your list switches it on.
Custom build Added on demand Fetched the first time you use it, then kept for offline use.

Comes with

Adding it brings these too. Engines are shared: each downloads once for every add-on that uses it.

Versions

VersionChannelDateWhat changed
0.11.1stableNovember 21, 2026Signed and published.
0.11.0stableNovember 20, 2026Signed and published.

Licence and maker

CadCraft (CadCraft, first-party). Licence: Apache-2.0. Dependencies carry their own licences, listed on their pages.