FeatureBuilt · in the lab

Dome spec: Sweden

The Sweden spec for the Dome generator, read in Boverket's own free text of the national application rules to the Eurocodes (EKS, to BFS 2022:4): the safety-class factor and load combinations, cover by exposure class and design life, limits for curved-roof snow, each value with its clause and how it was read. A thin pack: no thin-shell rule, no minimum shell thickness.

Use this add-on:

Lab Also adds 1 item it needs (3.1 MB).

Screenshots and a short video come with the listing (AL.3).

Overview

This spec reads 35 of the generator's rules plus 6 more: 15 of the 35 and 2 of the 6 were read, all in Boverket's own text of the Swedish national application rules to the Eurocodes (EKS, BFS 2011:10 as amended to BFS 2022:4, free from Boverket), and 20 of the 35 and 4 of the 6 not at all. Nothing was read in a second-hand document. It is a thin pack: Sweden has no thin-shell rule and no minimum shell thickness.

This is the Sweden spec for the Dome generator: what Sweden chose when it adopted the Eurocodes. EKS gives the safety-class factor gamma d (0.83, 0.91 or 1.0 for safety class 1, 2 or 3) that multiplies the load factors, the load combinations of Eurocode 0 as Sweden applies them (Tables B-1 to B-4: 1.35 on permanent actions, 1.5 on variable ones, the combination factors for snow, wind, imposed load and temperature), the cover for durability by exposure class and design life (Table D-1: 10 mm for dry indoor exposure XC1 and a 50-year life, 15 mm for 100 years), and its limits for snow on curved roofs. Because the factors depend on the safety class they are shown as sentences, not forced into one number: type the one your engineer picks into the box. Switch it on and pick it in the Dome generator's Spec section.

Not read: shell thickness, concrete grade, steel ratio as a number, earthquake factor (EKS names no earthquake standard), sprayed concrete, foam and fire, frost depth. A licensed engineer must design and check the dome; this is not a substitute for the standards.

Who it’s for

  • Designers of thin concrete domes who want the Dome generator's starting values and checks to come from the rules of Sweden, each with its source.
  • Engineers who review a dome and want every rule shown with its document, clause and how it was read.
  • Students and builders who want to see what the standards set for a shell, in one list.

What you can do

  • Fill the cover (10 mm, dry indoor exposure XC1, 50-year life) and the bar spacing limit (400 mm for slabs, the Eurocode's recommended value, as Sweden makes no other choice) where you left the boxes empty.
  • See each rule with its document, clause and how it was read, in the Dome generator's Spec section.
  • Read the Swedish load combinations and safety-class factor (gamma d 0.83, 0.91, 1.0) as sentences beside each load factor, and type the factors your engineer chooses.
  • Read the cover table by exposure class, the limits for snow on curved roofs and the rule on minimum steel in slabs as notes under Checks.

Methods and standards

A rule is used by the generator only when its value is a number in the unit the generator works in; here that is the cover and the bar spacing. Everything else is a sentence, shown beside its clause and not applied: your own figure always stands and is reported when it breaks a number the spec holds. The safety-class factor and the combination factors are sentences because they are not one figure. Documents: Boverket EKS (BFS 2011:10 as amended to BFS 2022:4) and EN 1992-1-1:2004.

Data and sources

The pack is made from research done on 2026-11-25, kept in the source as tools/dome/research/se.json: for every rule the value, the document, the clause, the page it was read on and the sentence read (Swedish quotes without diacritics). Of 35 rules, 15 were read and 20 not at all; of the 6 more rules, 2 were read. The pattern for uneven snow on a curved roof was read, the wind pattern for a dome was not. Documents: Boverket's EKS consolidated full text (BFS 2011:10 with amendments to BFS 2022:4) and, for the 400 mm bar spacing, the Eurocode 2 text as scanned by Public.Resource.Org (the Swedish rules say the Eurocode's recommended value applies where no national choice is made). EKS 11 (BFS 2019:1) was read as well and agrees on every value used.

Translated from Swedish by the pack's builder. The load factors are stated as EKS prints them (gamma d times 1.35 and 1.5, and so on) because they depend on the safety class.

Verification

CaseResult
Every value has its sourceResearched on 2026-11-25, kept in tools/dome/research/se.json: for every rule the value, the document, the clause, the page and the sentence read. Of 35 rules, 15 were read in the standard's own text; the other 20 carry no value and say so.
Dome spec tests140 checks pass and none fail (node bin/test-dome-specs.mjs, run 2026-11-28); they read each country pack's file, your own spec, and the review file for an engineer.

Limits

A design aid, not an engineering approval, and not a substitute for the standards or the national rules: a licensed engineer must design and check the dome. The values follow the Swedish national annex and rules to the Eurocodes; a rule with no value is shown without one and the generator does not guess it. A rule is used by the generator only when its value is a number in the unit it works in; sentences are shown, not applied. Your own figure always stands and is reported when it breaks a rule.

Files and formats

A data pack of rules in SI units with their sources, read by the Dome generator (format cadcraft-dome-spec, version 1). It reads and writes no files of its own; the dome's drawings, quantities and models come from the Dome generator. The review file for an engineer is made by the Dome generator.

Get started

  1. Add the Dome generator and this spec pack in Settings, Add-ons.
  2. Open the Dome generator and the Spec section.
  3. Pick the Sweden pack: it fills the boxes you left empty.
  4. Read each rule's document, clause and how it was read, and the rows that appear in Problems.

Languages

The text is available in:

  • English (en)

Works in

EditionWorksNote
Browser (/use) (yours) Added on demand Fetched the first time you use it, then kept for offline use.
Studio from getcadcraft.com Added on demand Fetched the first time you use it, then kept for offline use.
Microsoft Store Added on demand Fetched the first time you use it, then kept for offline use.
Google Play Added on demand Fetched the first time you use it, then kept for offline use.
iPad and iPhone (App Store) Included; switch it on Part of the reviewed app; your list switches it on.
Custom build Added on demand Fetched the first time you use it, then kept for offline use.

Comes with

Adding it brings these too. Engines are shared: each downloads once for every add-on that uses it.

Versions

VersionChannelDateWhat changed
0.12.1stableNovember 26, 2026Signed and published.

Licence and maker

CadCraft (CadCraft, first-party). Licence: Apache-2.0. Dependencies carry their own licences, listed on their pages.