FeatureBuilt · in the lab

Dome spec: United Kingdom

The United Kingdom spec for the Dome generator: cover, steel ratio, bar spacing and load factors from the UK National Annexes to the Eurocodes, with the uneven snow shape for curved roofs, each value with its document, clause and how it was read.

Use this add-on:

Lab Also adds 1 item it needs (3.1 MB).

Screenshots and a short video come with the listing (AL.3).

Overview

This is the United Kingdom spec for the Dome generator: a data pack of what the UK versions of the Eurocodes set for a thin concrete shell. Cover against earth, the minimum steel ratio and bar spacing come from the UK National Annex to Eurocode 2 (the 2004 text with its 2009 annex). The load factors for own weight, snow, wind and earthquake come from the UK National Annex to the basis-of-design Eurocode, with its choice between the two ways of writing the load combination. The snow shape the UK annex gives for a curved roof, with its figures, and the wind pressure pattern on a dome are there to read. Cover and the concrete class rest on a free guide of a trade body, because the British standard behind them is paid. Switch it on and pick it in the Dome generator's Spec section: its values fill the boxes you left empty, and the design is checked against the ones it holds as numbers.

Every value names its document and clause, and says whether we read it in the standard's own text, in a document that quotes it, or could not read it at all (then there is no value). No minimum shell thickness was read: the Eurocode sets none for shells, and the newest UK annex (2026) is paid. The UK annex to the wind Eurocode could not be opened, so UK wind figures are not read. It is not a substitute for the standards, and a licensed engineer must design and check the dome.

Who it’s for

  • Designers of thin concrete domes who want the Dome generator's starting values and checks to come from the rules of United Kingdom, each with its source.
  • Engineers who review a dome and want every rule shown with its document, clause and how it was read.
  • Students and builders who want to see what the standards set for a shell, in one list.

What you can do

  • Fill the Dome generator's empty boxes from the spec's values where it has one the generator can use.
  • See each rule with its document, clause and how it was read, in the Dome generator's Spec section.
  • Get a row in the result, and in Problems, for every figure that breaks a value in the spec.
  • Fill the load factors for own weight, snow, wind and earthquake, so the forces, the bending and the uplift check are factored.
  • Read the UK uneven snow shape for curved roofs, with its formulas for each slope, and the dome wind pressure pattern, as notes under Checks. The generator does not apply them: you type the pattern the forces use.
  • Read the rules the generator does not use as numbers (stability, tension steel, sprayed concrete documents, actions, combinations) beside the ones it does.

Methods and standards

A rule is used by the generator only when its value is a number in the unit the generator works in. A minimum raises a starting figure; your own figure always stands and is reported when it breaks the rule. Rules that are sentences (bar spacing as the code words it, stability, analysis, tension steel, sprayed concrete, standards for loads, combinations, partial factors, the modulus formula, openings, edge members) and the two patterns are shown, not applied. Documents: the UK National Annexes to BS EN 1990, 1991-1-3 and 1992-1-1, the text of BS EN 1992-1-1, 1991-1-3 and 1991-1-4, the scope pages of BS EN 14487, and The Concrete Centre's guide to Eurocode 2 with BS 8500.

Data and sources

The pack is made from research done on 2026-11-25, kept in the source as tools/dome/research/uk.json: for every rule the value, the document, the clause, the page it was read on and the sentence read. No value was typed from memory. Of 35 rules, 25 were read in the standard's own text (the UK National Annexes and the Eurocode text), 3 in a document that quotes the standard (cover, concrete class and steel yield, from a free trade-body guide and a trade-association page), and 7 not at all (minimum thickness, sprayed concrete strength and testing, foam and fire, frost, the published buckling guidance, foam outside a dome). Both pattern records (uneven snow on curved roofs, wind pressure pattern on domes) were read. The load factors are 1.35 on own weight, 1.00 where it helps, 1.5 on snow and on wind, 0.75 on snow with wind leading (1.5 times the printed 0.5), and 1.0 for earthquake. The annexes were read as copies published by Public.Resource.Org; the UK annex to the wind Eurocode could not be opened. The cover and the concrete class are for dry inside faces only. Several rules are slab or wall rules used as the nearest published figure for a shell, and the pack says so.

Four more rules sit beside the 35, and three were read: the factor on a floor's live load (in the UK annex itself), the lap rule (in the Eurocode 2 text) and the bend diameter rule (second-hand, in a free trade body guide); the hook extension is not read. The two pattern sentences are read and offered; the UK wind annex and BS 8500-1 are paid and were not read.

The factor on temperature for the shell analysis is 1.5 (gamma Q,i of the UK National Annex to EN 1990, Table NA.A1.2(B)); the factor on shrinkage was not read and stays 1.

Verification

CaseResult
Every value has its sourceResearched on 2026-11-25, kept in tools/dome/research/uk.json: for every rule the value, the document, the clause, the page and the sentence read. Of 35 rules, 25 were read in the standard's own text, 3 in a document that quotes it; the other 7 carry no value and say so.
Dome spec tests140 checks pass and none fail (node bin/test-dome-specs.mjs, run 2026-11-28); they read each country pack's file, your own spec, and the review file for an engineer.

Limits

A design aid, not an engineering approval, and not a substitute for the standards or the national rules: a licensed engineer must design and check the dome. The values follow the UK National Annexes to the Eurocodes; a rule with no value is shown without one and the generator does not guess it. A rule is used by the generator only when its value is a number in the unit it works in; sentences are shown, not applied. Your own figure always stands and is reported when it breaks a rule.

Files and formats

A data pack of rules in SI units with their sources, read by the Dome generator (format cadcraft-dome-spec, version 1). It reads and writes no files of its own; the dome's drawings, quantities and models come from the Dome generator. The review file for an engineer is made by the Dome generator.

Get started

  1. Add the Dome generator and this spec pack in Settings, Add-ons.
  2. Open the Dome generator and the Spec section.
  3. Pick the United Kingdom pack: it fills the boxes you left empty.
  4. Read each rule's document, clause and how it was read, and the rows that appear in Problems.

Languages

The text is available in:

  • English (en)

Works in

EditionWorksNote
Browser (/use) (yours) Added on demand Fetched the first time you use it, then kept for offline use.
Studio from getcadcraft.com Added on demand Fetched the first time you use it, then kept for offline use.
Microsoft Store Added on demand Fetched the first time you use it, then kept for offline use.
Google Play Added on demand Fetched the first time you use it, then kept for offline use.
iPad and iPhone (App Store) Included; switch it on Part of the reviewed app; your list switches it on.
Custom build Added on demand Fetched the first time you use it, then kept for offline use.

Comes with

Adding it brings these too. Engines are shared: each downloads once for every add-on that uses it.

Versions

VersionChannelDateWhat changed
0.12.1stableNovember 26, 2026Signed and published.
0.12.0stableNovember 25, 2026Signed and published.

Licence and maker

CadCraft (CadCraft, first-party). Licence: Apache-2.0. Dependencies carry their own licences, listed on their pages.