Dome spec: United States
The United States spec for the Dome generator: thin shell values from ACI 318.2 and the building code, each with its code, section and how it was read.
Use this add-on:
Overview
This is the United States spec for the Dome generator: a data pack of what the codes set for a thin concrete shell. Cover, concrete strength, the minimum steel ratio, bar spacing, and the rules on buckling, analysis and tension steel come from ACI 318.2, the thin shell code, read in its 2014 edition, the only one whose full text is free to read. Cover against earth is from ACI 318-19. What the International Building Code says about sprayed concrete, loads, foam insulation and frost was read in one state's adoption. Switch it on and pick it in the Dome generator's Spec section: its values fill the boxes you left empty, and the design is checked against the ones it holds as numbers.
Every value names its code and section, and says whether we read it in the code's own text, in a document that quotes the code, or could not read it at all (then there is no value). No minimum shell thickness was read: the 2014 code sets none, and the newer editions have a section on it that could not be read. The building code waives the thermal barrier over foam only where concrete covers it on each face; a sprayed dome has concrete on one face, which is a question for your building official. It is not a substitute for the codes, and a licensed engineer must design and check the dome.
Who it’s for
To be written (AL.3): the people and the jobs this serves (docs/0.8-SOUND-SPEC.md § 2 shows the depth expected).
What you can do
- Fill the Dome generator's empty boxes from the spec's values where it has one the generator can use.
- See each rule with its standard, clause and how it was read, in the Dome generator's Spec section.
- Get a row in the result, and in Problems, for every figure that breaks a value in the spec.
- Read the rules the generator does not use as numbers (buckling, analysis, tension steel, bar spacing, sprayed concrete testing, loads, foam and fire, frost) beside the ones it does.
- Fill the load factors for own weight, snow, wind and earthquake, so the forces, the bending and the uplift check are factored.
- Bring the rules that most need a decision (buckling, foam and fire, wind and snow on domes, openings) up as notes under Checks.
Methods and standards
A rule is used by the generator only when its value is a number in the unit the generator works in. A minimum raises a starting figure; your own figure always stands and is reported when it breaks the rule. Rules that are sentences (bar spacing as the code words it, one layer or two, buckling, analysis, tension steel, sprayed concrete documents and testing, loads, foam and fire, frost) are shown, not applied. Codes: ACI 318.2-14, ACI 318-19, the International Building Code 2021 and 2018 as adopted by one state, ASTM A615, and a state agency's and a trade association's papers where they quote those.
Data and sources
The pack is made from research done on 2026-11-20, kept in the source as tools/dome/research/us.json: for every rule the value, the code, the section, the page it was read on and the sentence read. No value was typed from memory. Values are in SI units with the inch or psi figure beside them. Researched again on 2026-11-21. Of 35 rules, 14 were read in the code's own text, 15 in documents that quote it, 6 not at all. The load factors (1.4 on own weight alone; 1.2 with other loads and 0.9 where it helps; 1.6 on snow; 1.0 on wind and earthquake) were read in the 2018 building code as one state adopted it, since the 2021 code only points to ASCE 7. Four rules are held back because the only pages found were ones we do not cite (wind and snow on domes, the stiffness formula, the buckling guidance): they say so. The 4,000 psi sprayed concrete strength is California's rule for public schools and hospitals and is shown, never used as a general minimum. Every shell value is from ACI 318.2-14, two editions back: check it against 318.2-19 or the 2025 edition. The sprayed concrete strength is the general floor for structural concrete, not a sprayed-concrete figure. The building code was read as Utah's adoption; your state or county may have another edition or amendments.
Verification
To be written (AL.3): benchmark cases and their results, linked to the verification manual (IND.1).
Limits
To be written (AL.3): what it does not do, and where its answers stop being good. Every engineering item says “a design aid, not an engineering approval”.
Files and formats
To be written (AL.3): what it reads and writes, and what it stores inside drawings.
Get started
To be written (AL.3): three steps and a sample file to open.
Languages
The text is available in:
- English (en)
Works in
| Edition | Works | Note |
|---|---|---|
| Browser (/use) (yours) | Added on demand | Fetched the first time you use it, then kept for offline use. |
| Studio from getcadcraft.com | Added on demand | Fetched the first time you use it, then kept for offline use. |
| Microsoft Store | Added on demand | Fetched the first time you use it, then kept for offline use. |
| Google Play | Added on demand | Fetched the first time you use it, then kept for offline use. |
| iPad and iPhone (App Store) | Included; switch it on | Part of the reviewed app; your list switches it on. |
| Custom build | Added on demand | Fetched the first time you use it, then kept for offline use. |
Comes with
- Dome generator 1.3 MB
Adding it brings these too. Engines are shared: each downloads once for every add-on that uses it.
Versions
| Version | Channel | Date | What changed |
|---|---|---|---|
| 0.11.1 | stable | November 21, 2026 | Signed and published. |
| 0.11.0 | stable | November 20, 2026 | Signed and published. |
Licence and maker
CadCraft (CadCraft, first-party). Licence: Apache-2.0. Dependencies carry their own licences, listed on their pages.