Feature

Pool spec: United States

The United States spec for the Pool generator: concrete shell and pool water values from ACI and the pool codes, each with its code, section and how it was read.

Use this add-on:

Sign in to add to every edition Also adds 1 item it needs (1.4 MB). Use offline Download as a file 68 KB
Pool generator spec table with ACI sources beside the 3D pool
Screenshot from the lab build. The Pool generator with the United States spec in force: 19 values read in the standards, 7 in documents that quote them, such as the exposure classes from ACI 318.
Rows of the United States pool spec with sources
More of the United States spec: shell strength 4000 psi from the ASA position statement and the other rules with their codes and how each was read.

Overview

This is the United States spec for the Pool generator: a data pack of the values that norms set for a concrete pool shell and its water circulation, taken from ACI 318 and ACI 350 (cover, strength, water to cement ratio, shrinkage steel, bar spacing), the American Shotcrete Association's pool position statements, the International Swimming Pool and Spa Code 2021 (turnover, pipe velocity, skimmers, inlets, suction outlets, barrier, deck slope), and the CDC Model Aquatic Health Code 2024 (filter rate, deck width, slip resistance). Switch it on and pick it in the Pool generator's Spec section: its values fill the boxes you left empty, and the design is checked against them.

Every value names its standard and clause, and says whether we read it in the standard's own text, in a document that quotes the standard, or could not read it at all (then there is no value). No United States code read is written for pool shells: the pool code sends structure to the building code, and the shotcrete association points to ACI 350. Most ACI values were read in documents that quote ACI, because ACI's text is not free to read. The pool code was read as one state's adoption; your state or county may have another edition or amendments. It is not a substitute for the standards, and a licensed engineer must design and check the pool.

Who it’s for

To be written (AL.3): the people and the jobs this serves (docs/0.8-SOUND-SPEC.md § 2 shows the depth expected).

What you can do

  • Fill the Pool generator's empty boxes from the spec's values where it has one the generator can use.
  • See each rule with its standard, clause and how it was read, in the Pool generator's Spec section.
  • Get a row in the result, and in Problems, for every figure that breaks a value in the spec.
  • Read the rules the generator does not use as numbers (exposure classes, crack width rule, leak test, slip classes, drain rules) beside the ones it does.

Methods and standards

A rule is used by the generator only when its value is a number in the unit the generator works in. A minimum raises a starting figure; a maximum lowers it; your own figure always stands and is reported when it breaks the rule. A rule that the source wrote for private or for public pools is applied to that use only. Rules that are labels, ranges or sentences are shown, not applied. Standards: ACI 318 and ACI 350 (cover, strength, water to cement ratio, shrinkage steel, bar spacing), the American Shotcrete Association's pool position statements, the International Swimming Pool and Spa Code 2021 (turnover, pipe velocity, skimmers, inlets, suction outlets, barrier, deck slope), and the CDC Model Aquatic Health Code 2024 (filter rate, deck width, slip resistance).

Data and sources

The pack is made from research done on 2026-11-19, kept in the source as tools/pool/research/us.json: for every rule the value, the standard, the clause, the page it was read on and the sentence read. No value was typed from memory. Values are in SI units; the pack says so where a value was converted. No United States code read is written for pool shells: the pool code sends structure to the building code, and the shotcrete association points to ACI 350. Most ACI values were read in documents that quote ACI, because ACI's text is not free to read. The pool code was read as one state's adoption; your state or county may have another edition or amendments.

Verification

To be written (AL.3): benchmark cases and their results, linked to the verification manual (IND.1).

Limits

To be written (AL.3): what it does not do, and where its answers stop being good. Every engineering item says “a design aid, not an engineering approval”.

Files and formats

To be written (AL.3): what it reads and writes, and what it stores inside drawings.

Get started

To be written (AL.3): three steps and a sample file to open.

Languages

The text is available in:

  • English (en)

Works in

EditionWorksNote
Browser (/use) (yours) Added on demand Fetched the first time you use it, then kept for offline use.
Studio from getcadcraft.com Added on demand Fetched the first time you use it, then kept for offline use.
Microsoft Store Added on demand Fetched the first time you use it, then kept for offline use.
Google Play Added on demand Fetched the first time you use it, then kept for offline use.
iPad and iPhone (App Store) Included; switch it on Part of the reviewed app; your list switches it on.
Custom build Added on demand Fetched the first time you use it, then kept for offline use.

Comes with

Adding it brings these too. Engines are shared: each downloads once for every add-on that uses it.

Versions

VersionChannelDateWhat changed
0.11.0stableNovember 21, 2026Signed and published.

Licence and maker

CadCraft (CadCraft, first-party). Licence: Apache-2.0. Dependencies carry their own licences, listed on their pages.