FeatureBuilt · in the lab

LOPA and SIL

Protection layers and SIL verification.

Use this add-on:

Lab Also adds 4 items it needs (4.5 MB).

Screenshots and a short video come with the listing (AL.3).

Overview

Planned. This add-on is not built and no host app mounts it. LOPA and SIL is planned (roadmap row CH.15) to take scenarios from HAZOP rows, add initiating-event frequencies and independent protection layers, and verify a safety instrument function with PFDavg for common voting architectures and proof-test intervals, using IEC 61511 arithmetic. A library for the arithmetic exists in the lab; no app uses it yet.

Who it’s for

  • Process safety and functional safety engineers.
  • Instrument engineers who verify safety instrument functions.
  • Teams who want scenarios to flow from the HAZOP without retyping.

What you can do

  • Nothing works yet. Planned: a scenario product of initiating frequency and protection layer failure probabilities, the gap to a target, the required reduction, and PFDavg for 1oo1, 1oo2, 2oo2, 1oo3 and 2oo3 voting with a common-cause factor (CH.15).

Methods and standards

Planned: the layer-of-protection product and the simplified PFDavg closed forms, with an exact time-average check. The library notes that detected-failure terms and architectural constraints are not covered.

Data and sources

You supply every frequency, failure probability, failure rate, proof-test interval and target. None is bundled; missing inputs are listed. The roadmap names failure data as user-supplied (IND.7).

Verification

Planned: no add-on test yet. The engine library behind it has a test, tools/process-test/test-safety.mjs, which the session log chem-safety_PART_3 records as 151 passed, 0 failed on 2026-10-28. It checks the library's arithmetic and file handling, not an add-on, and not against a worked example from a published guideline. The log lists the SIL bands and the simplified PFDavg equations as typed constants not yet confirmed.

Limits

Not built: high-demand PFH, detected-failure and repair terms, architectural constraint tables, protection layer credit rules, event trees, and any worksheet screen. A result is a study aid for a functional safety engineer, not a certified SIL assessment.

Files and formats

Planned: scenarios kept with the HAZOP worksheet in the drawing or project. No file is written today.

Get started

  1. Nothing to open yet. The add-on is planned and cannot be added.
  2. Watch the roadmap row named in this listing for when it is built and enters the lab.

Languages

No languages are listed for this add-on yet. Its maker may add some.

Works in

EditionWorksNote
Browser (/use) (yours) Added on demand Fetched the first time you use it, then kept for offline use.
Studio from getcadcraft.com Added on demand Fetched the first time you use it, then kept for offline use.
Microsoft Store Added on demand Fetched the first time you use it, then kept for offline use.
Google Play Added on demand Fetched the first time you use it, then kept for offline use.
iPad and iPhone (App Store) Included; switch it on Part of the reviewed app; your list switches it on.
Custom build Added on demand Fetched the first time you use it, then kept for offline use.

Comes with

Adding it brings these too. Engines are shared: each downloads once for every add-on that uses it.

Needed by: Instrumentation and control engineering, Process safety engineering.

Versions

VersionChannelDateWhat changed
1.0.0labOctober 31, 2026First version in the Library.

Licence and maker

CadCraft (CadCraft, first-party). Licence: Apache-2.0. Dependencies carry their own licences, listed on their pages.