Audit the model: rooms, tags, LOD, clashes and interfaces
Run ready checks for unnamed rooms, missing tags, elements below the level of development the project stage asks for, clashes between disciplines and LOD 350 interfaces. Advice only: nothing is blocked.
Written for BimCraft 0.10. The same help is inside the app: press F1.
What you'll do
Look over the whole model in one go before you issue it. The audit runs ready rule sets and puts what it finds in the Problems list as advice. Nothing is blocked: you fix a finding, or accept it with a reason, like any other problem.
Steps
- Open Model checks › Audit in the left panel, or Tools › Audit the model… (typed:
AUDIT). - Choose the Project stage. It is the same stage as in the drawing details.
- Tick the rule sets to run.
- Click Run the audit.
- Read the line for each rule set, then Open the Problems list. A click on a finding picks its element.
- The check report downloads the report: every finding, who accepted what and why, and the rule sets that ran.
The rule sets
- Unnamed rooms: a room with no name, or still called what the program called it ("Room 3").
- Missing tags: a door or window with no mark, a room with no number, an electrical device with no tag.
- Elements below the stage's LOD: each wall, floor, ceiling, roof, door and window whose LOD is under what the stage asks for. An element reads its type's LOD tag; a field-verified element is LOD 500. Elements with no tag are counted in one note, because they cannot be checked.
- Clashes between disciplines: elements of two disciplines (architecture, structure, mechanical, plumbing, electrical, by IFC class) that run into each other. A roof resting on its walls is not counted.
- LOD 350 interfaces: every door and window sits in an opening of its wall, the opening fits inside the wall, two openings do not overlap, an opening wider than the limit has a lintel or header (an element over it, or a note on the door or window), and a pipe, duct or cable tray that crosses a wall or slab has an opening there. Findings are counted per pair of disciplines.
- Recognised elements nobody has checked: walls, doors, windows and rooms read from a PDF, a scan or a drawing that are still unverified. See Mark elements as checked or field-verified.
The LOD each stage asks for
Open The LOD each stage asks for to see or change the table.
Good to know
- A lintel can be noted instead of modelled: pick the door or window and fill Lintel or header note under Verification in Properties.
- A pipe that passes through a real opening crosses no surface and is not reported. One that is modelled straight through the wall is.
- The clash check stops after a few seconds on a very large model and says so. For a full check of two chosen sets use Find clashes between elements.
- Run the audit again after you change the model. Accepted findings stay accepted while their numbers do not change.
- It reads the model. It does not replace a coordination review by the people responsible.